KLM-A
Home > Product > Medical category
Product model:KLM-A
Product Category:Medical category
Model specification:Routine + customizable
Order Hotline:+8613928121219

Product NameMulti-parameter detector

Product modelKLM-A

Specification  ①.Suttlet weight150Kg

②.DimensionHost):Bout 100cm length×72cm width×250cm heigh

③.Host Input VoltageAC100V-240V 50Hz/60Hz 1.0A

Product Main Structural Composition

It consists of height module, weight module, blood pressure module, forehead temperature module, blood oxygen probe, electrode (handle electrode and foot electrode) integrated circuit, base support, power line and mobile main body.

Intended purpose

The multi-parameter detector is used to measure the blood pressure (systolic pressure, diastolic pressure, and pulse rate), forehead temperature, and blood oxygen (pulse oxygen saturation) for adult (Weight more than 30Kg, height more than 140cm) in the clinic.

This product is certified as a medical device in the European Union under the Medical Device Regulation (EU) 2017/745 by SGS CE1639, exclusively for the indication(s) of “measurement of blood pressure, forehead temperature, blood oxygen”. Other medical/non-medical uses ascribed to this device are not within the scope of CE certification, and users should be aware product performance and/or safety has not been evaluated by SGS for those purposes。

Product technical parameters

Product Name

Multi-parameter detector

Model

KLM-A

Display Mode

12.1inch touch LCD

Blood pressure Measuring function

Measurement methods

oscillography measure

Measuring range

Pressure: 0kPa40kPa(0mmHg

300mmHg)

Pulse rate: 40 times/min199 times/min

Accuracy rating

pressure±0.4kPa(±3mmHg)

Pulse rate±5%

Arm circumferences

about 22cm36cm

Cuff pressure

0300mmHg

Clinical performance

Blood pressure Measuring function was clinically investigated according to the requirements of EN ISO 81060-2:2019.

Forehead temperature Measuring function

Rated output range

22.042.971.6109.2 

Laboratory accuracy

2242.9 ±0.3 

Display Resolution

0.1 (0.1)

Measuring Site

Forehead

Reference Body Site

Armpit

Body mode

Adjusted mode

Clinical accuracy

Clinical biasΔcb=-0.02 

LIMITS OF AGREEMENT, LA=0.18 

CLINICAL REPEATABILITY, σr,=0.07 

Blood oxygen measuring function

Measuring range

70%100%

Blood oxygen saturation measuring accuracy

±2%

Height measuring function

Measuring range

80cm205cm

Measuring accuracy

±1cm

Weight measuring function

Weighing range

5kg300kg

Maximum permissible

error of weighing

5 kg≤m≤50kg        ±0.3 kg

50 kgm≤100 kg     ±0.4 kg

100 kgm≤200 kg    ±0.8 kg

200 kgm≤300 kg    ±1.0 kg

Body impedance

Impedance measurement range

200Ω800Ω

Accuracy

±10%

Function

a)

Total moisture

b)

Protein

c)

Bone weight

d)

Fat weight

e)

Standard body weight

f)

Body mass index

g)

Percentage of body fat;

h)

waist-to-hip ratio

i)

skeletal muscle

j)

Visceral fat index

k)

Blood pressure

l)

Height value

m)

Physical age

n)

blood oxygen level

o)

body temperature

p)

basal metabolism

q)

voice broadcast

Power Supply

100V-240V 50Hz/60Hz 1A

Rated power

230VA

Normal working conditions

Ambient temperature540 

Relative humidity15 % 90% RH

Atmospheric pressure 700hPa

1060hPa

Transport and storage conditions

Ambient temperature- 20 50 

Relative humidity15% - 90% RH

Atmospheric pressure 500hPa

1060hPa

DimensionHost 

Bout 100cm length×72cm width×250cm heigh

Protection against electric shock

classequipment, BF type applied part

Liquid intake protection classification

IPX2

Disinfection and sterilization method

Clean as recommended by the manufacturer

Safety classification

Equipment not to be used in the presence of flammable anesthetic gas mixed with air or with oxygen or nitrous oxide

Fuse

T2AH250V 

Running Mode

continuous duty

EMC

1 group of class B devices